ASTM D Standard Test Method for Coulometric and Volumetric Determination of Moisture in Plastics Using the Karl Fischer Reaction (the Reaction of. ASTM D – 03() standard test method for coulometric and volumetric determination of moisture in plastics using the karl fischer reaction (the reaction of. ASTM D Standard Test Method for Coulometric and Volumetric Determination of Moisture in Plastics Using the Karl Fischer Reaction.

Author: Nasida Mazumi
Country: Denmark
Language: English (Spanish)
Genre: Software
Published (Last): 22 September 2011
Pages: 436
PDF File Size: 6.20 Mb
ePub File Size: 7.82 Mb
ISBN: 699-7-90412-812-7
Downloads: 98624
Price: Free* [*Free Regsitration Required]
Uploader: Fem

Since completing multiple co-op Most normal plant or lab operating conditions are adequate for sampling. Permission rights to photocopy the standard may also be secured from the ASTM website www. The water in the sample is vaporized and carried by dry oxygen free nitrogen into a reaction vessel with methanol. Originally approved in The solutions must be light amber in color. Water content in percent or parts per million is determined. NOTE 3—The condition of both anode and cathode solutions are determined by the appearance of the?

Also, hygroscopic materials like nylon absorb moisture and knowledge of the water content can be important in understanding performance. L of neutralization solution or check solution.

The volume of reagent that is added during the titration is measured and used to calculate the amount of moisture in the sample. If the cell potential shows a negative value, indicating that the anode solution contains excess iodine, add approximately 50 d6689 ? A number in parentheses indicates the year of last reapproval.

ASTM D6869

ASTM D – 03 standard test method for coulometric and volumetric determination of moisture in plastics using the karl fischer reaction the reaction of iodine with water 0. This is probably caused by the generation of water due to thermal decomposition or solid d68699 polymerization of the sample.

  CALENDAR TRIPTIC 2014 PDF

Industrial customers who have already been able to test the device are enthusiastic and are already now demonstrably saving time and analysis costs. No comments were found for ASTM D – 03 standard test method for coulometric and volumetric determination of moisture in plastics using the karl fischer reaction the reaction of iodine with water.

Sample d689 must be adequately dried and the environment in which sampling is performed must not add additional moisture to the sample. Two methods d6896 checking the instrument are listed here, a micro-capillary method and a sodium citrate method. As solutions age, viscosity will increase and solution color will turn dark. Standards can be obtained from appropriate standards authorities.

Sample size shall be adjusted to obtain an accurate moisture measurement. The permanganate index is an assessment of water quality typically used for freshwater and treated drinking waters.

The percent moisture in the sample is then calculated based on the sample weight used and is given as a direct digital readout.

It involves the determination of oxidizability, also known as oxygen O2 demand, by potassium permanganate ISO method This is how compEAct works — a sulfur and nitrogen analyzer from Analytik Jena developed for the petrochemical industry.

High moisture content causes surface imperfections that is, splay or bubbling or degradation by hydrolysis.

Moisture Content by Karl Fischer

The following table lists recommended sample weights for various moisture ranges: Sample size shall be adjusted to obtain an accurate moisture ashm. The directive relates to the quality of water intended for human consumption, ensuring it is safe and clean. Their electrode detects the current generated during the titration.

Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters.

The methanol traps the water which is asm to an end point with a Karl Fischer reagent to determine the amount present. Last previous edition approved in as D – It was not widely used because of the objectionable odor of pyridine.

  BAJO EL CIELO PROTECTOR PAUL BOWLES PDF

Removal of the previous sample will provide more accurate results. The new Thermo Scientific SOLA iQ online sulfur analyzer helps technicians, engineers and managers in the oil and gas industry measure total sulfur content of liquid or gas phase samples without requiring time-consuming lab analysis.

Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility.

The current or volume required to generate the iodine converts to ast of water present. A volumetric burette adds iodinecontaining reagent to the titration cell until no more current is generated. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Moisture Content by Karl Fischer ASTM D

Preparation of Apparatus Knowledge of the moisture content can be important since some polymers degrade when d869 wet resulting in reduced properties. Calculation or Interpretation of Results Halogenated alcohols especially tri? Take care not to get excess moisture on the outside surface of the capillary.

Summary of Test Method 2 3. The sample container shall be properly sealed to prevent moisture pick-up before testing. Customer comments No comments were found for ASTM D – 03 standard test method for coulometric and volumetric determination of moisture in plastics using the karl fischer reaction the reaction of iodine with water.