BS EN 1364-1 PDF

OF BOARD PARTITION SYSTEM. Client.: PalmEco Tech Ltd. Project.: Fire Resistance Test on Board Partition System in accordance with BS EN BS EN specifies a method for determining the fire resistance of non- loadbearing walls. This European Standard is used in. Find the most up-to-date version of BS EN at Engineering

Author: Shalabar Bagal
Country: Malaysia
Language: English (Spanish)
Genre: Environment
Published (Last): 3 July 2013
Pages: 242
PDF File Size: 5.1 Mb
ePub File Size: 12.64 Mb
ISBN: 558-9-26294-910-6
Downloads: 78066
Price: Free* [*Free Regsitration Required]
Uploader: Kajim

Walls No longer current but cited in Building Regulations guidance. B deformation of the wall shall be measured for later use as a basis for assessments. Radiation can be measured on uninsulated test items for E-Class and on test items having uninsulated areas greater than 0.

For vertical constructions there are also other functional requirements that can be used for classification. Fire dampers SS-EN The Amber document status indicator indicates that some caution is needed when using this document – it is either: Would you like to find out more about this test?

This part of EN specifies a method for determining the fire resistance of non-load-bearing walls. For determining the fire resistance of non-loadbearing walls and can be applied to internal and external non-loadbearing walls with and without glazing. EN Fire resistance tests for non-load-bearing 1364-11 — Part 1: According to the standard, different design solutions may not be mixed in a test such as different types of glass if it does not conform to the design solution used in practice.

  KADRI MIRZE ILETME PDF

The integrity of the structure is measured as usual with interpreters, cotton pad and visual observations.

BS EN – Fire resistance tests for non-loadbearing elements

Want access to British Standards? This document Older versions. National authorities in the member states may choose not to use all classes 13641- it is important to check which classes are of interest before testing. Otherwise, a vertical side should be free and the remaining three sides will be attached as in practice. If, in practice, the construction is less than 3×3 m, the wall must be attached in the same way as in practice.

The Red document status indicator indicates that the document is an old version The document has likely been withdrawn by the publisher, also the meta data presented here may be out of date as it is no longer being maintained by the editorial teams at NBS. For constructions with an anticipated insulation performance, thermocouples are mounted on the non-exposed side for measurement of average temperature and maximum temperature.

Covers equipment, test conditions, specimen and installation, test procedure and report. Walls European fire test method for non-load-bearing walls. Again there may be more recent versions of the document.

The tested object must be constructed as in practice. The classification standard EN defines the classes that can be used in Europe and the classes in the table below can be applied to non-load-bearing walls.

  IVT GEARBOX PDF

EN 1364-1 Fire resistance tests for non-load-bearing elements – Part 1: Walls

The method can be applied to non-load-bearing inner walls with or without glazing, walls consisting mostly of glass and other inner or outer walls with or without glazing. Their committees work with the manufacturing and service industries, government, businesses and consumers to facilitate the production of British, European and International standards.

If, in practice, the width or height of the construction is 3 m or less, then that dimension of the test specimen shall be tested at full size. Free to use Bd project management tool provides step-by-step help to define, manage and validate responsibility for information development and delivery at each stage of the asset life cycle in dn 2 BIM projects. Intended fire resistance Time minutes. The method is also applicable to windows.

Some countries, such as Sweden and Germany, require shock resistance, in this case shock tests must be performed according to EN Document Status Indicators The Green document status indicator indicates that the document is: The standard is to be applied in conjunction with EN Click here to find out how to access this document.

Author: admin